Heat and Moisture Exchanger with Filter McKesson 29.2 mg H2O / L @ VT 500 mL 2.5 cm H20 @ 30 LPM
$3.84
:In stock
Share:
McKesson # | 1109626 |
Manufacturer # | 16-6220 |
Brand | McKesson |
Manufacturer | McKesson Brand |
Country of Origin | Mexico |
Application | Heat and Moisture Exchanger with Filter |
Connection Type | 22 mm O.D. / 15 mm I.D. x 22 mm I.D. / 15 mm O.D. Port |
Dead Space | 26.77 mL |
Filter Efficiency BFE | 99.9% |
Filter Efficiency VFE | 99.9% |
Filter Type | Hygroscopic |
Is_Active_Vendor | Y |
Is_DSCSA | N |
Is_Discontinued | N |
Is_ECAT | N |
Is_GSA | N |
Is_Medical_Device | Y |
Is_VA | Y |
Lot_Tracking_Flag | N |
Moisture Output | 29.2 mg H2O / L @ VT 500 mL |
On_Allocation | N |
Port Type | Gas Sampling Port |
Resistance | 2.5 cm H20 @ 30 LPM |
Sterility | NonSterile |
Style | Straight |
Supplier_ID | 488035 |
UNSPSC Code | 42272219 |
User | Adult |
Volume | 150 to 1000 mL |
Latex Free Indicator | Not Made with Natural Rubber Latex |
Features
- McKesson Mini In-Line Heat and Moisture Exchanger with CO2 Port
- Mini design allows tidal volumes from 150 mL - 1000 mL for broad use among children and adults
- In-line design allows for use with gas elbow to fit to fit user preference
- For short-term airway humidification
- For the moisture and heat retention for return to the patient and provides filtration for prevention of breathing system contamination
- Optimal choice for enhancing the effectiveness of any breathing systems such as ventilators or anesthesia circuits
- Bacterial/viral filtration efficiencies in excess of 99.9%
- High moisture retention characteristics
- Clear housing to view levels of humidification
- Provide superior moisture output, minimum size, low breathing resistance
- True hygroscopic condensing humidifier (HCH) for maximal performance without potentially harmful chemicals
- Treated with physiologically safe calcium chloride, hygroscopic membrane traps patient’s moisture providing effective airway humidification
- Low resistance to airflow minimizes work of breathing
- Effective filtration reduces the risk of colonization in breathing tubes and minimizes sampling line blockage
- End tidal CO2 sampling port offers convenient access to airway gases
- Luer gas sampling ports for secure connection
- ISO-standard connections for secure, leak-resistant attachment to breathing systems
- Conveniently-located luer connection permits gas sampling at the top of the housing, just as if a common gas sampling elbow were being used
- Disposable available in convenient case quantities and individually-wrapped for single patient use
- Not Made with Natural Rubber Latex
- 1 Per Pack, 50 Packs Per Case